The purchaser will be responsible for return freight charges.
Conectar dos unidades para > 10 lpm Opciones de 8 lpm o 10 lpm El NewLife Intensity, newLife International Update - Spring 2013.
2.0 Operation Check and Oxygen Concentration Test. Table of ContentsSection 1.0Introduction1.1 1.2 1.3 1.4 Equipment Provider Responsibility Important Notice and Symbol Explanations NewLife Elite/NewLife Product Warranty Functional Specifications 1-1 1-2 1-4 1-5, Section 2.0Operation Check and Oxygen Concentration Test2.1 2.2 2.3 Description of Operation Operation Check Alarm System 2.3.1 2.3.2 2.4 Battery Test Power Failure Alarm Test 2-1 2-1 2-2 2-2 2-2 2-3, Oxygen Concentration Test and Specification, Section 3.0Patient Instructions3.1 3.2 General Instructions Routine Maintenance by the Patient 3.2.1 3.2.2 Cleaning the Air Intake Gross Particle Filter Checking the Alarm System Battery 3-1 3-1 3-1 3-2, Section 4.0Equipment Provider Maintenance4.1 Routine Maintenance 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.2AirSep Corporation, 4-1 4-1 4-1 4-2 4-2 4-3 4-3 4-4i table of contents, Air Intake Gross Particle Filter/GPF Product Filter Replacement Optional Filter Replacement Battery Replacement Recording Maintenance Preparing for New Patient Use, Section 5.0Service5.1 5.2 Components Cabinet Removal 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.3 5.3.1 5.3.2 5.4 5.4.1 5.4.2 5.4.3 5.5 5.5.1 5.5.2 5.6 5.7 Removing Side Panel(s) Removing Back Panel Removing Lower Front Cover Removing Control Panel Superstructure Caster Replacement Compressor Replacement Capacitor Replacement Feed or Waste Valve Rebuilding Feed or Waste Valve Reassembly Solenoid Valve Coil Replacement Sieve Bed Removal Sieve Bed Installation 5-1 5-1 5-1 5-1 5-1 5-1 5-1 5-2 5-2 5-3 5-4 5-4 5-4 5-5 5-5 5-6 5-6 5-7 5-7 5-8 5-8 5-9 5-10 5-10 5-10 5-11 5-12 5-13 5-14 5-14 5-14 5-14 5-14AirSep Corporation, Cabinet Fan Replacement Circuit Board Replacement 5.7.1 5.7.2 Circuit Board Removal Circuit Board Installation Setting Product Regulator for Normal Operation Product Regulator Lockout Back Pressure Correction at 5 lpm Product Regulator Cleaning or Rebuilding, Product Regulator Check and Setting 5.8.1 5.8.2 5.8.3 5.8.4, High or Low Pressure Switch Replacement (In Equipped Units) Circuit Breaker Replacement 5.10.1 5.10.2 Circuit Breaker Removal Circuit Breaker Installation ON/OFF Power Switch Removal, Buzzer Replacement Hour Meter Replacement Flowmeter Replacement 5.14.1 5.14.2 Flowmeter Removal Flowmeter Installation, Section 6.0Troubleshooting6.1 Operating Pressure Test 6.1.1 6.1.2 6.2 6.3 6.4 High Operating Pressure Low Operating Pressure 6-1 6-1 6-2 6-2 6-4 6-7, General Troubleshooting Troubleshooting Chart Tool Kit and Pressure Test Gauge, AppendixExploded DrawingsFigure 1: Control Panel Assembly Figure 2: Main Structure Assembly Figure 3: Base and Cabinet Components Figure 4: Test Block Assembly Figure 5: Valve Block Assembly Figure 6: Compressor Assembly Figure 7: Adsorption Bed Assembly A-1 A-2 A-3 A-4 A-5 A-6 A-7. It sounds an intermittent alarm if the high or low pressure indicators are activated or if the optional oxygen monitor detects lower than therapeutic levels of oxygen concentration. Instruct each patient how to perform routine maintenance of the air intake gross particle filter and how to check the alarm system battery. Seems that AirSep keeps their service manuals restricted. The AirSep NewLife Elite oxygen concentrator draws 350 Watts of power.
Listen for the sound. IT IS EXPRESSLY UNDERSTOOD THAT PURCHASERS SOLE AND EXCLUSIVE REMEDY FOR DEFECT IN PARTS IS LIMITED TO ENFORCEMENT OF AIRSEP CORPORATIONS OBLIGATION AS SET FORTH ABOVE, AND AIRSEP CORPORATION SHALL NOT BE LIABLE TO PURCHASER OR OTHERS FOR LOSS OF USE OF THE EQUIPMENT OR FOR OTHER SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUEN-TIAL DAMAGES. These responsibilities are outlined below and throughout this manual. The NewLife Elites Air Outlet feature allows the device to provide medicated nebulizer treatments in addition to supplemental oxygen. wide, 14.5 in. The NewLife must not be used as a life-supporting device. The AirSep NewLife Elite is an oxygen concentrator made by AirSep. 2Connect a calibrated oxygen concentration analyzer to the oxygen outlet. This enables proper treatment as prescribed by a qualified, licensed physician. http://www.lampworketc.com/forums/shd.php?t=178046, http://www.frankshospitalworkshop.coe_manuals.html, Currently Active Users Viewing This Thread: 1. wide, 14.5 in. To test the power failure alarm, take the following step: Unplug the unit, and set the ON/ OFF switch to the ON position. as for the oxycon Iall I know is that it has a plastic ribbed conection where the breathing hose attatched. (It takes approximately five minutes for the oxygen concentration to stabilize.)
6Adjust the flowmeter adjustment knob to the prescribed level. Disconnect the oxygen analyzer, and reconnect the humidifier bottle (if used) and any other equipment/ accessories that may be required. Repair components and replace parts only as outlined in this manual.
Always operate the unit for a reasonable length of time and check that the oxygen concentration level is within specifications as referred to in Section 2.4.
Turn the flowmeter adjustment knob counterclockwise until it stops (wide open). If an oxygen humidifier bottle is used, remove it from the oxygen outlet. No open flames within five feet of this device, oxygencarrying tubing, or accessories.
I have a Nortel Minor torch I want to run this on with propane.
NewLife Elite / NewLife Oxygen Concentrator Service Manual, 0459AirSep Corporation 401 Creekside Drive Buffalo, NY 14228-2085 USAAirSep Corporation, Telephone: (716) 691-0202 24-Hour Fax: (716) 691-4141, Expedited Product Warranty Check service is always at your fingertips with AirSep: Type www.airsep.info/warranty_check/main.asp OR In the US or Canada, dial 866-873-9277. Locate the Patient Manual in the pocket on the back of each unit. By creating an account, you agree to our terms and conditions. Each adsorber produces oxygen for approximately eight seconds and delivers it to the product tank. Inspect the condition of each NewLife unit immediately upon delivery to your business location. least six inches of open space on all sides for ventilation. Refer to the NewLife Product Warranty if parts replacement is required within the warranty period. The maximum flow should register 5.5 lpm (the 5.5 lpm line should appear to split the middle of the flowmeter ball) with no connections at the oxygen outlet. Unpack the unit and remove it from the carton. 4Perform an oxygen concentration test, as described in Section 2.4. Operating Environment: 41 F to 104 F (5C to 40C), up to 95% humidity, Storage Environment: -4 F to 140 F (-20C to 60C), up to 95% relative humidity, 2022 iFixit Licensed under Creative Commons Privacy 2.4Oxygen Concentration Test and Specification. AirSep Corporations obligations under this warranty are limited to the repair or replacement of any such item of equipment (or part thereof) shown to be defective or, at AirSep Corporations option, to refunding the purchase price of any such defective item of equipment. At five liters per minute, the air produced is approximately 90-percent oxygen. (Test the battery and power disconnect alarm as described in Section 2.3 of this manual.). No oil, grease or petroleum-based products on or near the unit. Inspect the unit itself for damage. Instruct each patient how to perform routine maintenance of the air intake gross particle filter and how to check the alarm system battery. Each item of equipment for which a warranty claim is asserted shall, at the request of AirSep Corporation, be returned on a prepaid basis with proof of purchase date to the AirSep factory at the expense of the purchaser. ????
The flow control valve, which is part of the flowmeter, controls the amount of oxygen delivered to the patient. Use only AirSep parts for replacement in NewLife Oxygen Concentrators.
CAUTION: Describes a hazard or unsafe practice that can result in minor bodily injury or property damage. Do not measure oxygen concentration output after the product stream passes through a humidifier bottle, or erroneous readings will result. Next, a two-way solenoid feed valve directs the air into one of two sieve beds that contain molecular sieve.
When operated between one and three liters per minute, the air produced is approximately 95-percent oxygen. Introduction1.1 Equipment Provider ResponsibilityAll Equipment Providers of the NewLife Elite/NewLife Oxygen Concentrator must assume responsibilities for handling, operational check-out, patient instruction, and maintenance. The filter may require daily cleaning if the NewLife unit operates in a harsh environment such as a house heated by wood, kerosene, or oil, or one with excessive cigarette smoke.
Note any sign of damage, external or internal, on the delivery receipt, and report it directly to both the freight company and AirSep Corporation immediately. 5Disconnect the oxygen analyzer, and reconnect the humidifier bottle (if used) and any other equipment/ accessories that may be required. Inspect the condition of each NewLife unit immediately upon delivery to your business location. 3Verify that the product flow rate delivered by the unit matches the patients prescription and does not exceed the capacity of the unit. 1Open and inspect all cartons (that contain units) upon delivery.
Instruct patients how to use the NewLife in conjunction with the Patient Manual. The audio alarm must sound loudly for approximately five seconds each time the unit is turned to ON to indicate the battery is in good condition. Check the operation of each NewLife before delivery to a patient. As you read the manual, pay special attention to the WARNING, CAUTION, and NOTE messages. !Maintain the NewLife in accordance with Section 4.0.
Adjust the flowmeter adjustment knob to the prescribed level. high, 15.7 in. Neither iFixit nor this repair information is endorsed by or affiliated with the medical device manufacturer. Remove the dirty air intake gross particle filter from the back of the NewLife unit, and install the clean filter stored in the pocket on the back of the unit. Verify that the product flow rate delivered by the unit matches the patients prescription and does not exceed the capacity of the unit. Enter your email address and check your inbox. !Check the operation of each NewLife before delivery to a patient.
This should immediately activate the audio alarm. c.Exhaust air flows out of the bottom of the unit.
deep (72.4 cm high, 40.0 cm wide, 36.8 cm deep) 54.0 lb; shipping weight - 59.0 lb (24.5 kg; shipping weight - 29.0 kg) 120 VAC, 60 Hz, 4 amps, 350 watts 23. Each item of equipment for which a warranty claim is asserted shall, at the request of AirSep Corporation, be returned on a prepaid basis with proof of purchase date to the AirSep factory at the expense of the purchaser. 4Place the clean air intake gross particle filter in the pocket on the back of the unit.
Expedited Product Warranty Check service is always at your fingertips with AirSep: Type www.airsep.info/warranty_check/main.asp. Clean the air intake gross particle filter. Replacement parts shall be warranted as stated above for the unexpired portion of the original (one-, three-, or five-) year parts warranty (as specified on the original invoice provided). "), AirSep Corporation 401 Creekside Drive Buffalo, NY 14228-2085 USA, Telephone: (716) 691-0202 24-Hour Fax: (716) 691-4141. Accessibility. Low liter flow is between 0.125-2 liters per minute.
An oxygen concentrator is a medical or industrial device that concentrates the oxygen from either ambient air or another gas supply. (Refer to Section 3.2.) A backup supply of oxygen must be available.
Oxygen concentrators selectively remove nitrogen and other gases from the air to provide an oxygen-enriched stream. Maintain the NewLife in accordance with Section 4.0. They identify safety guidelines or other important information as follows: WARNING: Describes a hazard or unsafe practice that can result in severe bodily injury or death. 4Set the units ON/OFF power switch to the ON position. THE FOREGOINGWARRANTYIS IN LIEU OFANYOTHERWARRANTY, EXPRESSED OR IMPLIED, IN FACT OR IN LAW, INCLUDING WITHOUT LIMITATION THE WARRANTY OF MERCHANTABILITYOR THEWARRANTYOF FITNESS FOR PARTICULAR PURPOSE. You must explain that the purpose of this therapy is to alleviate symptoms. !Deliver NewLife units only to patients authorized by a physicians prescription.
ITIS EXPRESSLYUNDERSTOODTHATPURCHASERSSOLEANDEXCLUSIVEREMEDYFOR DEFECTIN PARTS IS LIMITED TO ENFORCEMENTOFAIRSEPCORPORATIONS OBLIGATIONAS SET FORTHABOVE,ANDAIRSEPCORPORATION SHALLNOT BE LIABLE TO PURCHASER OR OTHERS FOR LOSS OF USE OF THE EQUIPMENT OR FOR OTHER SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUEN-TIALDAMAGES.
Instruct patients to notify their physicians and/or Equipment Providers if they experience any signs of discomfort.
As an Equipment Provider, you must do all of the following: ! Note any sign of damage, external or internal, on the delivery receipt, and report it directly to both the freight company and AirSep Corporation immediately. Connect a calibrated oxygen concentration analyzer to the oxygen outlet. The NewLife Oxygen Concentrator is equipped with a battery-powered alarm system, which sounds a continuous and loud alarm when a power failure occurs. Refer to Section 6.0 for a list of probable alarm causes. Set the units ON/OFF power switch to the. Pressurized air then exits the compressor and passes through a heat exchanger. The AirSep NewLife Elite oxygen concentrator is advertised to deliver between one and five liters per minute of oxygen. Place the clean air intake gross particle filter in the pocket on the back of the unit. The NewLite Elite concentrator can be identified by the name NewLife Elite printed in large cursive font on the front of the device. Unpack the unit and remove it from the carton. If so are there mods needed like psi change etc. We're working on it and we'll get it fixed as soon possible. Use only AirSep parts for replacement in NewLife Oxygen Concentrators.
The unique property of molecular sieve enables it to physically attract (adsorb) nitrogen when air passes through this material, thus producing high concentration oxygen. 3Use a soft absorbent towel to remove excess water. !Instruct each patient how to perform routine maintenance of the air intake gross particle filter and how to check the alarm system battery. AirSep is a registered trademark of AirSep Corporation.! Exhaust air flows out of the bottom of the unit. Open and inspect all cartons (that contain units) upon delivery. As an Equipment Provider, you must do all of the following: !Inspect the condition of each NewLife unit immediately upon delivery to your business location. AirSep Corporations obligations under this warranty are limited to the repair or replacement of any such item of equipment (or part thereof) shown to be defective or, at AirSep Corporations option, to refunding the purchase price of any such defective item of equipment. Repair components and replace parts only as outlined in this manual. I just purchased a newlife elite airsep concentrator 5lpm for 100 bucks today in Houston!!! The name AirSep is also printed in cursive font on the front of the machine. AirSep is a registered trademark of AirSep Corporation. A continuous alarm loudly sounds for approximately five seconds to indicate that the battery for the alarm is good.
Air enters the NewLife Oxygen Concentrator through an external air intake gross particulate filter. Always operate the unit for a reasonable length of time and check that the oxygen concentration level is within specifications as referred to in Section 2.4. Refer to the NewLife Product Warranty if parts replacement is required within the warranty period. any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". No open flames within five feet of this device, oxygencarrying tubing, or accessories. Terms !Repair components and replace parts only as outlined in this manual. The one that comes with the machine is most likely the patient manual, which is very restrictive as to any internal service data and internal adjustments. and could I get a copy of the service manual(s) or instructions on modifying the machine?
This warranty does not extend to any item or part subjected to misuse, accident, improper maintenance, or application, or which has been repaired or altered outside of the AirSep Corporation Factory without the express prior written authorization of AirSep Corporation.THE FOREGOING WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, IN FACT OR IN LAW, INCLUDING WITHOUT LIMITATION THE WARRANTY OF MERCHANTABILITY OR THE WARRANTY OF FITNESS FOR PARTICULAR PURPOSE. Functional SpecificationsDimensions: Weight: Electrical Requirements: Capacity: Accuracy: Concentration: 28.5 in. d.OPTIONAL: The Oxygen Monitors amber light remains on until the oxygen concentration reaches 85% 3% (approximately two minutes). Wash the dirty filter in warm soapy water, and rinse. Advise patients to immediately notify their Equipment Providers and/or physicians in case of an alarm or any discomfort. The NewLife unit delivers up to 95.5% pure oxygen at flow rates from 15 lpm. Use a soft absorbent towel to remove excess water. The compressor runs. Use only AirSep parts for replacement in NewLife Oxygen Concentrators. PDF file AirSep NewLife Elite CONCENTRADOR DE OXGENO ESTACIONARIO ESTABLECIENDO ESTNDARES Con un rendimiento superior.
Replacement parts shall be warranted as stated above for the unexpired portion of the original (one-, three-, or five-) year parts warranty (as specified on the original invoice provided).
Check to see that the following occurs: a.A continuous alarm loudly sounds for approximately five seconds to indicate that the battery for the alarm is good. Instruct patients to notify their physicians and/or Equipment Providers if they experience any signs of discomfort. The following harmonized symbols (pictograms), used for nonEnglish language countries, will be located on the exterior of the NewLife unit: No smoking within five feet of this device, oxygencarrying tubing, or accessories. b.The compressor runs.
It is important that patients thoroughly understand how to operate the AirSep NewLife unit. I have no clue what-so-ever as to how to hook it up or what I need to do it with, I did get two different hoses with my torch, one green and one red. To ensure that the units output of oxygen is within specification, you must perform a test of oxygen concentration. The purchaser will be responsible for return freight charges. All Equipment Providers of the NewLife Elite/NewLife Oxygen Concentrator must assume responsibilities for handling, operational check-out, patient instruction, and maintenance. NewLife units must not be used for or with any lifesupporting applications. To ensure accurate output and efficient operation of the unit, the patient must perform two simple routine maintenance tasks: !Clean the air intake gross particle filter, 3.2.1 Cleaning the Air Intake Gross Particle Filter. 1Remove the dirty air intake gross particle filter from the back of the NewLife unit, and install the clean filter stored in the pocket on the back of the unit. The following harmonized symbols (pictograms), used for nonEnglish language countries, will be located on the exterior of the NewLife unit: No smoking within five feet of this device, oxygencarrying tubing, or accessories. Location: A Little Bit West of Yosemite Valley. Important Notice and Symbol ExplanationsAs you read the manual, pay special attention to the WARNING, CAUTION, and NOTE messages.
What these numbers indicate will most likely be covered in the service manual. These responsibilities are outlined below and throughout this manual.
Found the patient manual online, but not the service manual. AirSeps solutions are designed as an alternative to gas generators and gas cylinders. !Instruct patients how to use the NewLife in conjunction with the Patient Manual. (Test the battery and power disconnect alarm as described in Section 2.3 of this manual. Be the first to ask a question! An oxygen concentrator is a medical or industrial device that concentrates the oxygen from either ambient air or another gas supply.
Advise patients to immediately notify their Equipment Providers and/or physicians in case of an alarm or any discomfort.
(Refer to Section 3.2.). AirSep tests every NewLife Oxygen Concentrator thoroughly after manufacture. If patients experience any discomfort or the unit alarms, they must notify their Equipment Provider and/or physician immediately. NOTE: Provides information important enough to emphasize or repeat. Plug in the power cord of the unit, and set the ON/OFF switch to the. They identify safety guidelines or other important information as follows: Describes a hazard or unsafe practice that can result in severe bodily injury or death. Instruct patients how to use the NewLife in conjunction with the Patient Manual.
Describes a hazard or unsafe practice that can result in minor bodily injury or property damage.
- Vintage Terracotta Pots Large
- Vintage Hanging Chain Lamps
- Wrought Iron Patio Furniture Canada
- Harry Potter Scholastic Illustrated
- Granular Ammonium Sulfate
- Gilders Paste Wax Color Chart
- Metabo Guide Rail Compatibility
- Moonstone Necklace - Supernal
- Ecommerce Product Trends 2022
- The Summit Hotel Lexington Ky
- Ford Escape Rear Frame Rust
- Samsung Silicone Zfold 3 Case
- Bugaboo Butterfly Newborn